The Bradbury Family has been Serving Your Air Conditioning, Heating & Plumbing Needs for 30+ Years

Our family are experts when it comes to Cooling, Heating and Plumbing services for your homes and businesses. Our family gives you our personal promise that we won’t be happy until you’re 100% satisfied! Our reputation is based on your 100% satisfaction, and we take that promise seriously. It’s a part of our company mission!

Call us now at (281) 651-5484 or (936) 271-2030 for fast and friendly service. We’d love the opportunity to earn your business as we have with your Shenandoah, TX neighbors.

See what your neighbors are saying about our services below!

Local Reviews
for Shenandoah, TX

Bradbury Brothers Cooling, Plumbing & Electrical Rated 4.9 out of 5 stars based on 44 customer reviews


Great




Review of Bradbury Brothers Cooling, Plumbing & Electrical

I believe the gentleman's name, who I dealt with was Luis. Your crew did a great job. Thanks 🙏🏼


Great install




Review of Bradbury Brothers Cooling, Plumbing & Electrical


AC time up visit




Review of Bradbury Brothers Cooling, Plumbing & Electrical

Very thorough and answered my questions well.


Great Service




Review of Bradbury Brothers Cooling, Plumbing & Electrical


Good service




Review of Bradbury Brothers Cooling, Plumbing & Electrical

Professional


Great service




Review of Bradbury Brothers Cooling, Plumbing & Electrical

Casey was professional and friendly, answering all my questions


Excellent b




Review of Bradbury Brothers Cooling, Plumbing & Electrical

Excellent Service


Response from Bradbury Brothers Cooling, Plumbing & Electrical:

Thank you for the 5 stars, Kathy!


Foley Review




Review of Bradbury Brothers Cooling, Plumbing & Electrical


Thank you, Mike!! Amazing!!!




Review of Bradbury Brothers Cooling, Plumbing & Electrical

Michael was the best! Truly awesome. He was very knowledgeable and extremely helpful to my husband and I during our bathroom renovation and our plumbing needs. This was our first experience with Bradbury Brothers and definitely won’t be our last because of his great craftsmanship. Thank you so much!!!


Great




Review of Bradbury Brothers Cooling, Plumbing & Electrical


Good service




Review of Bradbury Brothers Cooling, Plumbing & Electrical

Your techs always find something to cost us money.


Owner




Review of Bradbury Brothers Cooling, Plumbing & Electrical


Good job




Review of Bradbury Brothers Cooling, Plumbing & Electrical


Super AC Check up




Review of Bradbury Brothers Cooling, Plumbing & Electrical

On time, thorough and done in a timely manner. Considerate to others who are working from home.


Owner




Review of Bradbury Brothers Cooling, Plumbing & Electrical


Excellent Service and Customer Care




Review of Bradbury Brothers Cooling, Plumbing & Electrical

As always, Bradbury Brothers provided excellent service, explanation of procedures, and customer care through Fernando, today’s technician. They were extremely careful in safety precautions for us and their technician due to the COVID-19 virus. They went above and beyond in replacing a part that was still working, but with diminished capacity. We would normally have to wait for that part to fail completely, and consequently shut down the whole unit, for the warranty to replace that part. We are retired and Fernando did not want us to suffer in case that part failed during our hot summer. He spoke with the “brothers” and they decided to replace this part with NO CHARGE to us! Family caring and service is what makes this company exceptional. Please call Bradbury Brothers for all you HVAC needs!


Response from Bradbury Brothers Cooling, Plumbing & Electrical:

Thank you, Linda! We are so happy to hear Fernando took great care of you. #1 in our values statement is taking great care of our customers, so it is wonderful to hear that Fernando took this to heart. We want you and your home to be prepared for a very HOT summer! Thank you so much for taking the time to write us such a nice review, and for giving us the opportunity to serve you.


Great service




Review of Bradbury Brothers Cooling, Plumbing & Electrical

Quick, yet thorough, quality work


Response from Bradbury Brothers Cooling, Plumbing & Electrical:

Thank you for the review, Laura! So happy to hear this about your visit with Nic!


He's great




Review of Bradbury Brothers Cooling, Plumbing & Electrical


Response from Bradbury Brothers Cooling, Plumbing & Electrical:

Thank you for the 5 stars, Jill!


Excellent




Review of Bradbury Brothers Cooling, Plumbing & Electrical


Response from Bradbury Brothers Cooling, Plumbing & Electrical:

Thank you so much, John!


Great Service




Review of Bradbury Brothers Cooling, Plumbing & Electrical

Technician was very knowledgeable, explained everything in detail. He was very polite.


Response from Bradbury Brothers Cooling, Plumbing & Electrical:

Thank you, Kathy! We aim for 100% satisfaction with our people, and are always so excited when we hear that our team members were knowledgeable and polite. Thank you for taking the time to write us.


Great guys




Review of Bradbury Brothers Cooling, Plumbing & Electrical


Response from Bradbury Brothers Cooling, Plumbing & Electrical:

Thank you, Jill!


Good service




Review of Bradbury Brothers Cooling, Plumbing & Electrical

Checked heaters and replaced parts that needed to be replaced.


Response from Bradbury Brothers Cooling, Plumbing & Electrical:

Thank you, Gary! Glad to hear everything went well.


Great Service




Review of Bradbury Brothers Cooling, Plumbing & Electrical


Response from Bradbury Brothers Cooling, Plumbing & Electrical:

Thank you for the 5 stars, Cody!


Great




Review of Bradbury Brothers Cooling, Plumbing & Electrical

Was not able to find a problem today. Will come back if the situation arises again. Friendly and courteous


Response from Bradbury Brothers Cooling, Plumbing & Electrical:

Thank you for the review, John! We are happy to hear you found Jeremy to be friendly and courteous. Thank you for giving us the opportunity to serve you.


Very professional and helpful approach!




Review of Bradbury Brothers Cooling, Plumbing & Electrical

Jeremy was very thorough, knowledgeable, and willing to help. May have helped us save some money by addressing a leak problem effectively.


Response from Bradbury Brothers Cooling, Plumbing & Electrical:

Thank you, Jama! We aim to help our customers save money, and improve comfort & safety in their homes. We are so happy to hear that Jeremy helped you fix a leak that should help you save some money. Thank you for taking the time to write us this review!


Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Michael C.

Came out today to change out customer supply faucet. The Faucet is changed out in the box with the old Faucet is in the mudroom area. We tested the new one and no leaks, and we also diagnose the issues with the tankless water heater. We have an estimate coming their way to change the parts out and will get them ordered so we can get that fixed. Customer paid with credit card, and we will get the parts quickly and get back out to fix the tankless.

Near Pine Brook Ct, Shenandoah, TX 77381
Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Ken P.

AC Diagnostic Site Contact: Roger System: Server room Refrigerant Type R410A Metering Device- EXV SP- 30 VSAT- -15 Outdoor Entering Air Temperature 85 Returned tstat to original settings: Y Unit operational prior to leaving: Y Notes: Server room unit not cooling. Found system low on refrigerant. Talked to Jeff and he authorized added 2 pounds of refrigerant. Found the leak with electronic leak detector in the Indoor coil. Will have office check warranty and send estimate for repair. Once he receives estimate Jeff will decide if we wants to proceed with repair or wait and see how long refrigerant lasts. After adding refrigerant Refrigerant Type R410A Metering Device- EXV SP- 122 SLT- 90 VSAT- 41 SH- 6 Outdoor Entering Air Temperature 85

Near Interstate 45 N, Shenandoah, TX 77385
Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Jim V.

Arrive to the customers house to do an annual home inspection. At the time of the inspection everything looks safe and in good working order. I only found two items which I wrote estimates for. The one item I was able to fix the other item will need a return visit. . Make sure that the 2nd floor GFI is working properly in bathroom ( unable to fix the GFI IT HAS BAD WIRING AND WILL NEED TO COME BACK ) We temporarily bypassed the outlet for safety reasons. We need to re-attach plug and cover to the eve on the side of the house so that it will be working properly again.

Near Pine Brook Ct, Shenandoah, TX 77381
Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Marc H.

Came back out today to replace Vortens Dual flush flush valve on downstairs powder room bathroom. Tested out and everything is working properly.

Near N Parkgate Cir, Shenandoah, TX 77381
Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Henry M.

System- Goodman Approx Age of System: 2 Refrigerant Type-R410a Metering Device- TXV SP/HP:137.3/321.9 SLT/LLT:50.6/90.7 VSAT/LSAT- 47.8/101.1 Superheat/Subcool-2.6/10.1 Outdoor Entering Air Temp-75 Outdoor Fan FLA- .8 Compressor RLA/LRA-9.3/95.6 Contactor Voltage-248.2/26.1 Capacitor Rating-44.72/5.02 Indoor Return Dry Bulb Temp-72.1 Return Wet Bulb Temp-62.6 Supply Temp- 54.8 Temperature Difference-17.3 Required Difference- 16-20 Blower FLA- 3.9 Filter Sizes – 20x25x4 Changed Filters – Y( customer provided) Blew out drain line: y Returned tstat to original settings: Y(75) Unit operational; prior to leaving: Y Notes-Upon arrival, located equipment and made the call for cooling, system kicked on accordingly. Refrigerant pressures are within manufacture specifications for current outdoor temperature. Found compressor was exceeding LRA value on the data plate. Compressor has a strain on it when starting up. Recommend adding compressor saver to the system to aid

Near Ed English Dr, Shenandoah, TX 77385
Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Ronald E.

System- Downstairs Approx Age of System: 7 Refrigerant Type-R410a Metering Device- Fixed Orifice SP/HP: 136/356 SLT/LLT: 66/108 VSAT/LSAT- 47.7/108 Superheat/Subcool- 19/6 Outdoor Entering Air Temp- 93 Outdoor Fan FLA- 1.20 Compressor RLA/LRA- 11.0/89.9 Contactor Voltage- 244/24 Capacitor Rating- 45/10 Indoor Return Dry Bulb Temp- 78 Return Wet Bulb Temp- 68 Supply Temp- 56 Temperature Difference- 22 Required Difference- 15-20 Blower FLA- 6.10 Filter Sizes – 20x30x1 Changed Filters – clean Blew out drain line: N (no access) Returned tstat to original settings: Y Unit operational; prior to leaving: Y System- upstairs Approx Age of System: 7 Refrigerant Type-R410a Metering Device- Fixed Orifice SP/HP: 141/353 SLT/LLT: 60/103 VSAT/LSAT- 49/107 Superheat/Subcool- 11/6.5 Outdoor Entering Air Temp- 93 Outdoor Fan FLA- .84 Compressor RLA/LRA- 6.24/62 Contactor Voltage- 244/25 Capacitor Rating- 35/5 Indoor Return Dry Bulb Temp- 80 Return Wet Bul

Near Bella Sole, Shenandoah, TX 77381
Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Casey L.

Front office mini split (Rodgers office) Found system low on refrigerant. Added 2 lbs of R410 to the system. Brought the VSAT from 8 degrees to 46 degrees. This unit has a known leak in it. At this time the unit is cooling. The split system for the meeting also wasn’t cooling. Found bad contractor. This contactor took out the fuse and the transformer. Replaced fuse transformer and contactor to restore cooling checked pressures after the repair. Pressures look good at this time. SP 138 HP 325 SLT 62 LLT 95 VSAT 40 LSAT 101 SH 13 SC 7

Near Interstate 45 N, Shenandoah, TX 77385
Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Shane B.

Arrived to backed up drains in kitchen. Customer has recently had grease trap cleaned. First channel in grease trap is full and doesn’t appear to have been cleaned since it won’t pull out of slot. Used shovel to break up grease at bottom of first channel to make it drain. Snaked out drain with grease head and flushed with hot water. All drains are flowing.

Near Research Forest Dr, Shenandoah, TX 77381
Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Ernest P.

Replaced all 8 filters.

Near Research Forest Dr, Shenandoah, TX 77381
Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Ernest P.

System- s# 5615J02231 Approx Age of System: 5 Refrigerant Type- R410a Metering Device- TXV SP/HP: 142/337 SLT/LLT: 57/91 VSAT/LSAT- 49/104 Superheat/Subcool- 7/12 Outdoor Entering Air Temp- 82 Outdoor Fan FLA- 1.0 Compressor RLA 5.2 Contactor Voltage- 473 Capacitor Rating- 10 Indoor Return Dry Bulb Temp- 70 Return Wet Bulb Temp- 60 Supply Temp- 51 Temperature Difference- 19 Required Difference- 17 Blower FLA- 2.4 Filter Sizes – 20x25x2 (4) Changed Filters – N Blew out drain line: y Returned tstat to original settings: Y Unit operational; prior to leaving: Y Notes- performed ac tuneup. System was operational upon arrival. System- s# 5615D04391 Approx Age of System: 5 Refrigerant Type- R410a Metering Device- TXV SP/HP: 141/332 SLT/LLT: 58/90 VSAT/LSAT-48/102 Superheat/Subcool-10/12 Outdoor Entering Air Temp- 82 Outdoor Fan FLA- 0.5 Compressor RLA/LRA- 4.0 Contactor Voltage- 474 Capacitor Rating- 6.5 (7.5) Indoor Return Dry Bulb Temp- 69 Re

Near Research Forest Dr, Shenandoah, TX 77381
Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Marc H.

Homeowner had us back out today to change out pop up assembly in downstairs powder room bathroom. Changed out and tested everything is working properly.

Near N Parkgate Cir, Shenandoah, TX 77381
Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Jason T.

Installed 12x12 Cut In

Near Bella Sole, Shenandoah, TX 77381
Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Jason T.

Approx Age of System: Refrigerant Type- R22 / R410a Metering Device- Fixed Orifice / TXV SP/HP: SLT/LLT: VSAT/LSAT- Superheat/Subcool- Outdoor Entering Air Temp- Outdoor Fan FLA- Compressor RLA/LRA- Contactor Voltage- Capacitor Rating- Indoor Return Dry Bulb Temp- Return Wet Bulb Temp- Supply Temp- Temperature Difference- Required Difference- Blower FLA- Filter Sizes – Changed Filters – Y/N Blew out drain line: Y/N Returned tstat to original settings: Y/N Unit operational; prior to leaving: Y/N Notes- Scheduled next tune up date: Approx Age of System: Refrigerant Type- R22 / R410a Metering Device- Fixed Orifice / TXV SP/HP: SLT/LLT: VSAT/LSAT- Superheat/Subcool- Outdoor Entering Air Temp- Outdoor Fan FLA- Compressor RLA/LRA- Contactor Voltage- Capacitor Rating- Indoor Return Dry Bulb Temp- Return Wet Bulb Temp- Supply Temp- Temperature Difference- Required Difference- Blower FLA- Filter Sizes – Changed Filters – Y/N Blew out drain lin

Near Bella Sole, Shenandoah, TX 77381
Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Jason T.

System- Main Approx Age of System: 1 Refrigerant Type- R410a Metering Device- TXV SP/HP:134/348 SLT/LLT:60/95 VSAT/LSAT- 47/105 Superheat/Subcool-12/10 Outdoor Entering Air Temp-94 Outdoor Fan FLA- R1.2 A.8 Compressor RLA/LRA-R17.9/112 A10.7/109 Contactor Voltage-242.4/25.6 Capacitor Rating-45/5 47.1/4.8 Indoor Return Dry Bulb Temp-76 Return Wet Bulb Temp-64 Supply Temp- 59 Temperature Difference-17 Required Difference-15-20 Blower FLA- 3.4 Filter Sizes – 20x25x1. 4-12x12x1 Changed Filters – N (Customer will replace) Blew out drain line: Y Notes- System was operational upon arrival. Performed ac tune up found no issues. Scheduled next tune up date: Nov 10, 10-2

Near Saddlewood Cir, Shenandoah, TX 77381
Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Ken P.

Replaced complete AC condensate line installed a p trap and installed in line safety switch. Bathroom was being remodeled and contractor had cut away the vent leaving me nothing to connect I ran the condensate line up up the vent stack location. Had to wait for contractor working in bathroom to cut new tee into vent stack then reconnected the condensate line to the vent stack.

Near Blue Ridge Dr, Shenandoah, TX 77381
Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Ken P.

AC Diagnostic System: Upstairs Refrigerant Type R410A Metering Device-Fixed Orifice SP/HP 144/356 SLT/LLT 59/101 VSAT/LSAT 50/108 SH/SC 9/7 Outdoor Entering Air Temperature 97 Filter Size(s) 20x25 Returned tstat to original settings: Y Unit operational; prior to leaving: Y Notes: Called out for upstairs not cooling. I found the system to be cooling fine. Mr Hoffman said it’s not really the whole floor but mainly one room. The room in question he said gets the most sun. I also found that it’s room directly above the garage and next to the attic access and mr. Hoffman said that they do typically keep the door to this room closed. I recommended adding a return to the room and an attic stairway insulator to the attic access. Mr Hoffman would like to have the return added, scheduled return visit for Wednesday between 10-2

Near Bella Sole, Shenandoah, TX 77381
Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Ken P.

Drain line had backed up again and caused the safety switch to trip. We blew it out two weeks ago I recommended that we replace the condensate drain line. Mrs. Nowicki was not happy that she was not given the option to replace initially. After talking to the service manager she has approved waiving the diagnostic charge and the charge for the new blow out valve. Mrs. Nowicki was happy with this arrangement. Office will call tomorrow to schedule return visit to replace drain line. Tonight I cleared the drain again with nitrogen and cleaned water from the emergency pan at no charge per the service manager.

Near Blue Ridge Dr, Shenandoah, TX 77381
Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Ronald E.

System- Main Approx Age of System: 10 Refrigerant Type- R410a Metering Device- TXV SP/HP: 126/336 SLT/LLT: 63/102 VSAT/LSAT- 43/103 Superheat/Subcool- 18/3.0 Outdoor Entering Air Temp- 90 Outdoor Fan FLA- .56 Compressor RLA/LRA- 7.73/68 Contactor Voltage- 239/24 Capacitor Rating-49/4.9 Indoor Return Dry Bulb Temp- 74 Return Wet Bulb Temp- 68 Supply Temp- 55 Temperature Difference- 19 Required Difference-15-20 Blower FLA- 5.10 Filter Sizes – 16x40x1 16x25x1 Changed Filters – Customer will replace Blew out drain line: Y System- Bedroom Approx Age of System: 10 Refrigerant Type- R410a Metering Device- TXV SP/HP: 110/316 SLT/LLT: 71/102 VSAT/LSAT- 38/99 Superheat/Subcool- 34/0 Outdoor Entering Air Temp- 90 Outdoor Fan FLA- 1.13 Compressor RLA/LRA- 11.53/ Contactor Voltage- 238/24 Capacitor Rating- 45/7.5 Indoor Return Dry Bulb Temp- 76 Return Wet Bulb Temp- 66 Supply Temp- 56 Temperature Difference- 20 Required Difference- 15-20 Blo

Near Markham Grove Pl, Shenandoah, TX 77384
Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Ken P.

AC Diagnostic System: Downstairs Refrigerant Type R410A Metering Device-TXV SP/HP 119/333 SLT/LLT 46/94 VSAT/LSAT 40/102 SH/SC 6/8 Outdoor Entering Air Temperature 90 Filter Size(s) 20x25x4 Notes: Came out for no cooling on the downstairs unit. The condenser fan would not come on during a call for cooling because of a dead capacitor. Mrs. Miller approved replacement of the capacitor and after doing so I checked the system for proper oppression. While in the attic found the filters were dirty and replaced them with customer provided filters. The system is operating within manufacturers specifications at this time.

Near S Parkgate Cir, Shenandoah, TX 77381
Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Ken P.

AC Diagnostic System: RTU 10 Refrigerant Type R410A Metering Device-TXV SP/HP 149/328 SLT/LLT 75/93 VSAT/LSAT 52/102 SH/SC 23/8.9 Outdoor Entering Air Temperature 90 Return temperature- 81 Supply temperature- 61 Temperature Difference- 20 Static Pressure Return- 0.35 Supply- 0.75 TESP- 1.10 Notes: RTU 10 in receiving area not cooling. It was 81 in receiving area the thermostat is off site. Checked the system and it working within manufacturers specifications. Previous technician assessed that the unit was too small for its space. After today’s findings I agree that system. Bigger unit is required to cool receiving room. Talked to Jeffery on the phone, he is would like to receive an estimate for upsizing the system. Field Manager will get in contact with estimate.

Near Interstate 45 N, Shenandoah, TX 77385
Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Ronald E.

System- U/S Approx Age of System: 4 Refrigerant Type- R410a Metering Device- TXV SP/HP: SLT/LLT: VSAT/LSAT- Superheat/Subcool- Outdoor Entering Air Temp- Outdoor Fan FLA- .60 Compressor RLA/LRA- 8.33 Contactor Voltage- 240/45 Capacitor Rating- 45/5 Indoor Return Dry Bulb Temp- 73 Return Wet Bulb Temp- 63 Supply Temp- 55 Temperature Difference- 22 Required Difference- 15-20 Blower FLA- 4.25 Filter Sizes – 20x25x4 Changed Filters – clean Blew out drain line: Y System- Downstairs Approx Age of System: 4 Refrigerant Type- R410a Metering Device- TXV SP/HP: SLT/LLT: VSAT/LSAT- Superheat/Subcool- Outdoor Entering Air Temp- Outdoor Fan FLA- .88 Compressor RLA/LRA- 6.50 Contactor Voltage- Capacitor Rating- Indoor Return Dry Bulb Temp- 72 Return Wet Bulb Temp- Supply Temp- 54 Temperature Difference- Required Difference- 15-20 Blower FLA- 7.20 Filter Sizes – 16x25x4 Changed Filters – clean Blew out drain line: N Notes- performed ac

Near McGoey Cir, Shenandoah, TX 77384
Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Casey L.

System- Downstairs Approx Age of System: 2 years Refrigerant Type- R410a Metering Device- TXV SP/HP: 121/328 SLT/LLT:58/88 VSAT/LSAT-41/103 Superheat/Subcool-17/14 Outdoor Entering Air Temp-86 Outdoor Fan FLA- 1.78 Compressor RLA/LRA-10.91 Contactor Voltage-245/27 Capacitor Rating-N/A Indoor Return Dry Bulb Temp-77 Return Wet Bulb Temp-68 Supply Temp-57 Temperature Difference-20 Required Difference-16 Filter Sizes – 20x25x4 (2) Changed Filters – Yes. Customer supplied Blew out drain line: yes Notes- Unit is cooling and functioning as it should. No visible issues with this unit at this time. _____________________________________________ System- Upstairs Approx Age of System: 12 years Refrigerant Type- R410a Metering Device- TXV SP/HP: 129/321 SLT/LLT: 73/92 VSAT/LSAT- 45/101 Superheat/Subcool-28/9 Outdoor Entering Air Temp-86 Outdoor Fan FLA- 0.55 Compressor RLA/LRA-6.05/89.2 Contactor Voltage-245/27 Capacitor Rating-34.64/4.74 Indoor Re

Near Silverwood Ranch Estates, Shenandoah, TX 77384
Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Fernando G.

System- single system Approx Age of System: 3 Refrigerant Type- R410a Metering Device- TXV SP/HP: 127.3/286.5 SLT/LLT: 56.7/91.4 VSAT/LSAT- 43.8/92.7 Superheat/Subcool- 12.9/1.3 Outdoor Entering Air Temp- 81 Outdoor Fan FLA- .4 Compressor RLA/LRA- 7.9/51.7 Contactor Voltage- 249 Capacitor Rating- 40/4 Indoor Return Dry Bulb Temp- 78 Return wet bulb- 47.8 Supply Temp- 55.5 Temperature Difference- 22.5 Required Difference- 16-20 Blower FLA- 3.6 Filter Sizes – 20x25x4 Changed Filters – Y (customer supplied) Blew out drain line: Y Notes- unit is running within manufacture specifications at this time only recommendation was a minor condenser coil cleaning approved and taken care of today. Next Scheduled Tune up Date: Due to current health events going on Mr. Tom would like to wait and schedule the next tuneup closer to the fall season follow up needed. . . . . . . . . .

Near Blue Ridge Dr, Shenandoah, TX 77381
Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Casey L.

System- Downstairs Approx Age of System: 7 years old Refrigerant Type- R410a Metering Device- TXV SP/HP: 128/308 SLT/LLT: 57/89 VSAT/LSAT- 44/95 Superheat/Subcool-13/7 Outdoor Entering Air Temp- 80 Outdoor Fan FLA- 1.15 Compressor RLA/LRA- 9.45/96.5 (112 rated) Contactor Voltage-247/27 Capacitor Rating-46.24/9.90 Indoor Return Dry Bulb Temp-72 Return Wet Bulb Temp-60 Supply Temp-53 Temperature Difference-19 Required Difference-16 Filter Sizes – 20x30x1 Changed Filters – No Blew out drain line: Yes. Notes- At this time the unit is cooling properly. All refrigerant levels, voltages, amp draws and capacitors look good at this time. The unit is missing condensation protection. We have a package that includes 2 float switches that shut the 7nit down if the drain lines back up. This prevents ceiling damage if the emergency drain pan overflows. I highly recommend this package to help prevent any major issues and headaches in the future. Scheduled next tun

Near Bella Sole, Shenandoah, TX 77381
Air Conditioning, Heating & Plumber Reviews in Shenandoah, TX

Casey L.

PO#26411 RTU#2 Model RKKL-B120DN15E S#F361600766 Return and replace in warranty compressor Recover refrigerant Remove and dispose of existing in-line filter drier and contactor as per manufacturer industry standards. Furnish and Install (1) Copeland Scroll style compressor, contactor and in-line filter drier. Furnish and Install acid-away neutralizer. Pressurize with nitrogen to ensure all newly soldered copper connections are leak free prior to evacuation. Evacuate and charge with refrigerant (13lbs) Check unit for proper operations Includes our process to complete repairs start to job completion. (labor, acid away, nitrogen, acetylene, oxygen, silver solder, filter drier, refrigerant, compressor, freight, and warranty processing through the manufacturer.

Near Interstate 45 N, Shenandoah, TX 77385