The Bradbury Family has been Serving Your AC Repair, Heating & Plumbing Needs for 30+ Years

AC, Heating & Plumbing Services | Willis, TX

Our family are experts when it comes to Air Conditioning, Heating & Plumbing your homes and businesses near Willis, TX. Our family gives you our personal promise that we won’t be happy until you’re 100% satisfied! Our reputation is based on your 100% satisfaction, and we take that promise seriously. It’s a part of our company mission!

Call us now at (281) 651-5484 or (936) 271-2030 for fast and friendly service. We’d love the opportunity to earn your business as we have with your Willis, TX neighbors.

See what your neighbors are saying about our services below!

Recent Jobs and Reviews in Willis, TX

Rated 4.8 out of 5 stars based on 80 customer reviews

Job Locations and Reviews

Review
Charles has worked on our plumbing several times and has done an excellent job every time!
Nellie - Willis, TX 77318
Response from Bradbury Brothers Cooling, Plumbing & Electrical:

Thanks for leaving us such a wonderful review. We are glad that you loved our services, our dedicated staff will be pleased to learn of your high praise.

Ticia R.
Ticia R. Checked in
Plumbing Diagnostic
Willis, TX 77318
Mario S.
Mario S. Checked in
AC Diagnostic System:main Control for surge protector are no longer functional, will need to have surge protector replaced tomorrow. Bypassed the surge protector to get the unit operational tonight . Nobody will be home to replace the surge protector, so if we are needing to drop the temperature for any reason Sam asks that we call him so he can control it by phone.
Willis, TX 77318
James W.
James W. Checked in
Customer had us out today for a slow draining sink in the master bath. Ran hand top to clear blockage. Filled and drained the sink multiple times to test for leaks and functionality, everything is operating as it should. No warranty on drain cleaning.
Willis, TX 77318
Mario S.
Mario S. Checked in
System-main Approx Age of System: 8 Refrigerant Type- R410a Metering Device- TXV SP/HP:118/298 SLT/LLT:62/94 VSAT/LSAT- 46/102 Superheat/Subcool-16/7.6 Outdoor Entering Air Temp-78 Outdoor Fan FLA- 1.1 Compressor RLA/LRA-12.1/74 Contactor Voltage-28/220 Indoor Return Dry Bulb Temp-74 Supply Temp-56 Temperature Difference-18 Required Difference-16-22 Blower FLA- 3.2 Filter Sizes – 20x25x1 Changed Filters – Y (customer provided) Blew out drain line: N no blow out valve Returned tstat to original settings: Y Unit operational; prior to leaving: Y Notes-System is fully operational, filter was dirty and replaced. No other issues were visible, Scheduled next tune up date:Jan 21st 8-10
Willis, TX 77378
Ernest P.
Ernest P. Checked in
Diagnostic Found 55/5uf run cap failed. Replaced with Turbo 200. System function restored. 90/292 psi 58/112 lt 52/130 sat 4/16 shsc Condenser coil is starting to deteriorate. System is running very hot. Compressor is struggling audibly at start up. System utilizes r22. Based on age, conditions and operational concerns - system replacement is recommended. Trust owned home.
Willis, TX 77318
Michael C.
Michael C. Checked in
We came out today to conduct the annual plumbing home inspection. We ended up giving an estimate to replace the cartridge in the upstairs guest bathroom tub, replace the angle stops and supply lines in that same bathroom sink because they were polybutylene and most likely will one day be a serious issue, and to replace the supply line on the Toilet in that bathroom because it’s a problematic product and not recommended. Also gave an estimate to the customer to replace the water heater because they know it is all then near the end of its life expectancy but assured them we will be replacing it with the same quality rheem Product. Other than that the house looks great no serious issues to bring up to the customer and they will call us when they’re ready to make these repairs.
Willis, TX 77318
Review
My situation was effectively analyzed and addressed in an effective manner. I was pleased with the result.
Thomas - Willis, TX 77318
Response from Bradbury Brothers Cooling, Plumbing & Electrical:

We are pleased to know your experience with us was a good one!

Michael C.
Michael C. Checked in
Came out today to give the customer pricing on changing out the water heater in the garage. Customer okayed the estimate and we went ahead with the work. The customer now has a new 40 gallon electric water heater installed with a pan. Customer paid with credit card no follow-up needed today.
Willis, TX 77318
Jeremy D.
Jeremy D. Checked in
System- Main Approx Age of System: 5yrs Refrigerant Type- R410a Metering Device- Fixed Orifice SP/HP: 122/303 SLT/LLT: 59/86 VSAT/LSAT- 41/96 Superheat/Subcool- 17/10 Outdoor Entering Air Temp- 82 Outdoor Fan FLA- 1.2 Compressor RLA/LRA- 10.3/117 Contactor Voltage-242/26 Capacitor Rating- 68.01/14.75 Indoor Return Dry Bulb Temp-75 Return Wet Bulb Temp- 59 Supply Temp- 55 Temperature Difference- 20 Required Difference- 16-20 Filter Sizes – 20x30x1 Changed Filters – Acceptable Blew out drain line: Y Returned tstat to original settings: Y Unit operational; prior to leaving: Y Notes- Unit was operational on arrival. Checked filters. Checked operating pressures and temperatures. Checked indoor and outdoor electrical. Condenser LRA is over rating of 117a. All other components showed no visible issues at this time. Recommend compressor saver-(to reduce amp and extend equipment life). Installed compressor saver. Checked operation. Scheduled next tune up date
Willis, TX 77318
Review
Thorough job
Lee - Willis, TX 77318
Henry M.
Henry M. Checked in
AC Diagnostic System:main Refrigerant Type R410A Metering Device-TXV SP/HP105.5/342.7 SLT/LLT74.5/96.4 VSAT/LSAT34.4/105.1 SH/SC40/8.7 Outdoor Entering Air Temperature 90 Filter Size(s)20x25x4(Lennox media filter) Returned tstat to original settings: Y(did not touch) Unit operational; prior to leaving: Y Notes:Upon arrival, Mr.Cotton explained that we had been out last month and cleared the drain line but when he went up to the attic recently he saw there was water in the drain pan. The unit is upflow and the secondary drain port to the coil was capped off so water was overflowing in the primary drain line going through the blower and existing out of the seams of the bottom of the furnace. Homeowner authorized fixing drain line to have secondary port drain into the emergency drain pan. Explained that there was a large amount of rust on the coil and there is a high chance of primary drain line getting clogged again. When recording unit pressures, found the suction pressure low for
Willis, TX 77318
Review
Jim with Bradbury Brothers was extremely knowledgable and so very easy to talk with. A true professional.
Ronnie - Willis, TX 77318
Jim V.
Jim V. Checked in
Arrived to the Rector residence to go over generator ideas. Got information for Todd and Ron that way we can put a price together. At this time there’s no reason to do a follow up call.
Willis, TX 77318
James W.
James W. Checked in
Customer had us out today for a leak on the main line. Found the 90 going towards the house leaking. Made the repair, allowed glue to cure for 20 minutes and turned water back on. No signs of leaking and everything seems to be working as it should.
Willis, TX 77318
Jeremy D.
Jeremy D. Checked in
AC Diagnostic System: Refrigerant Type R410A Metering Device- TXV SP/HP 141/375 SLT/LLT 61/98 VSAT/LSAT 49/111 SH/SC 11/13 Outdoor Entering Air Temperature 90 Filter Size(s) 20x25x1 Returned tstat to original settings: Y Unit operational; prior to leaving: Y Notes: Unit is operational on arrival. Checked safety switches. Water is present in emergency drain pan. Checked operating temperatures and pressures. Head pressure is a little high. No issue. Primary drain line is clogged/restricted. Cleared drain line and checked for flow. Recommendations: Drain line flush, condenser coil clean
Willis, TX 77318
Review
I'm not disappointed in Ernest, but I am disappointed that the unit is not performing as intended. I spent over $15,000 on this unit and I was told that it would be sufficient for my building. The unit cannot keep the temp below about 78 or 80 degrees during the afternoon. Ernest told me that someone would contact me and I haven't been contacted.
Stephen - Willis, TX 77378
Caleb C.
Caleb C. Checked in
Master shower as constantly running. Shower cartridge wS bad and needed to be replaced . Turned water off and installed new moen cartridge and tested for leaks. Found none
Willis, TX 77318
Ernest P.
Ernest P. Checked in
Run capacitor failure. Replaced with Turbo 200, system function restored. System is over amping on startup despite having a functional hardstart. R22 system. Filter dryer is rusting out. Condenser coil is deteriorating. Replacement is strongly recommended. RP- .12 /FR- .38 /FS- .29 /SP- .1 TESP: .67 Skylar scheduled 07/03 5-6
Willis, TX 77318
Shane B.
Shane B. Checked in
Free water test and filter install estimates. Customer has bought her own aquasona system and would like us to install it. Estimates provided and will be installed Wednesday
Willis, TX 77318
Ernest P.
Ernest P. Checked in
139/300 psi 48/95 sat 13/8 shsc 61/87 lt 83 DB 72 WB 67 ST 16 split 15 Target System function is where it should be. No issues with unit function. Spoke with Stephen on the phone. Thermostat was running on schedule. - moved to hold.
Willis, TX 77378
Fernando G.
Fernando G. Checked in
System- single system Approx Age of System: 14 Refrigerant Type- R22 Metering Device- TXV SP/HP: 63.4/164.4 SLT/LLT: 48.5/78.2 VSAT/LSAT- 36.4/88.4 Superheat/Subcool- 12.1/10.2 (dirty coils/dirty evap coil) Outdoor Entering Air Temp- 77 Outdoor Fan FLA- .7 Compressor RLA/LRA- 8.4/46.6 Contactor Voltage- 244.8 Capacitor Rating- 43/5 Indoor Return Dry Bulb Temp- 68.2 Return Wet Bulb Temp- 43 Supply Temp- 49.7 Temperature Difference- 18.5 (heavily impacted coils) Required Difference- 16-20 Blower FLA- 5.2 Filter Sizes – 20x30x1 Changed Filters – N (customer will replace at later time) Blew out drain line: Y Returned tstat to original settings: Y Unit operational; prior to leaving: Y Notes- System has heavy organic growth over the evaporator coil as well as heavy corrosion. Due to the age and condition of the equipment doing a major cleaning on the indoor coil’s and outdoor coils may not be more beneficial as refrigerant leaks are at a higher risk after cl
Willis, TX 77318
Review
👍👍👍👍👍
Lee - Willis, TX 77318
Ken P.
Ken P. Checked in
AC Diagnostic System: Bedrooms Refrigerant Type: R410A Metering Device- TXV SP/HP 138/302 SLT/LLT 73/94 VSAT/LSAT 48/96 SH/SC 24/2 Outdoor Entering Air Temperature 83 Returned tstat to original settings: Y Unit operational; prior to leaving: Y Notes: Bedrooms unit not cooling. Found the thermostat kept reverting back to the schedule no matter what time you set on the temporary hold. Theres was no permanent Hold options, but if you turned off the schedule it was equivalent to a permanent hold with schedule turned off system operating properly. Offered replacement thermostat. Mr Cotton had a spare thermostat in his workshop from when the zoning system was disabled asked me to move that one over. When I removed it found that the battered had leaked battery acid all over the thermostat control board. Mr Cotton decided not to move the thermostat over and just use the old one with the schedule turned off. While in attic I saw that his main unit had a backed up drain line. Mr Cotton appro
Willis, TX 77318
Michael C.
Michael C. Checked in
Came out to conduct the plumbing inspection, everything looks good. Would suggest putting the tankless flush on schedule and we left pricing in the email but wouldn’t be able to during normal business our since they have to have hot water. Also noted the small backflow for the ice maker looks worn and to keep an eye on that, but the plumbing checked out other than that.
Willis, TX 77318
Marc H.
Marc H. Checked in
Homeowner had us out today because he is moving and was trying to unhook the washing machine. The cold side shut off valve would not shut off. Homeowner authorized to change the cold side. Made repair everything is working properly.
Willis, TX 77318
Juan  M.
Juan M. Checked in
AC Diagnostic System: Refrigerant Type R410A Metering Device-TXV SP/HP 127/234 SLT/LLT60/90 VSAT/LSAT43/99 SH/SC 23/5 Outdoor Entering Air Temperature 89 Filter Size(s) 20x25x1 12x12x1 14x25x1 Returned tstat to original settings: Y Unit operational; prior to leaving: Y Notes: Upon arrival system was on but not cooling. Condenser was on and blower motor was on checked refrigerant levels and they are ok. Went to attic and found bypass open all the way checked each damper motor and all were open. Closed bypass and home started cooling. System is operating at this time. Recommendations:
Willis, TX 77318
Caleb C.
Caleb C. Checked in
Garbage disposal was leaking internally and dripping on bottom cabinet. Showed home owner options for replacing .they went with new 3/4 horse power. Installed and checked for leaks. Found none . Put in new air filters for home owner as well. Home owner also had two toilet seats for me to install. Installed them and they were set and not moving
Willis, TX 77318
Matt F.
Matt F. Checked in
Final Inspection
Willis, TX 77378
Review
I would recommend this company to others.
Alicia - Willis, TX 77318
Ernest P.
Ernest P. Checked in
System- single Approx Age of System: 8 Refrigerant Type- R410a Metering Device- TXV SP/HP: 127/293 SLT/LLT: 62/84 VSAT/LSAT- 43/94 Superheat/Subcool- 19/9 Outdoor Entering Air Temp-79 Outdoor Fan FLA- 1.3 Compressor RLA/LRA- 11.1/129.6 Contactor Voltage- 247/27 Capacitor Rating- 45/5 Indoor Return Dry Bulb Temp- 77 (66) Supply Temp- 60 Temperature Difference- 17 Required Difference- 17 Blower FLA- 7.6 Filter Sizes – 20x25x1 Changed Filters – N (Clean) Blew out drain line: Y Notes- performed ac tuneup. System was operational upon arrival. Found compressor over amping on startup. No overflow protection inline - installed inline condensation protection. Next Scheduled Tune up Date: 11/03 10-2 . . . . . . . . .
Willis, TX 77318
James W.
James W. Checked in
AS PER AGREEMENT
Willis, TX 77378
Review
I'm very pleased with the job that Jim performed in making the electrical connection to the new HVAC unit that was installed by Bradbury Brothers. Jim was very prompt at arriving at the time agreed upon and did a very nice job. Thank you
Steve - Willis, TX 77378
Review
Henry was courteous, and explained about the features in my system he checked.
Frank - Willis, TX 77318
Review
Job well done
Lee - Willis, TX 77318
Response from Bradbury Brothers Cooling, Plumbing & Electrical:

Thank you for the 5 stars, Lee!

Review
Very helpful options for w/h replacement
Lee - Willis, TX 77318
Response from Bradbury Brothers Cooling, Plumbing & Electrical:

Thank you for the 5 stars, Lee!

Review
He did a fine job.
Barbara - Willis, TX 77318
Review
Very knowledgeable and very courteous!!
Jed - Willis, TX 77318
Response from Bradbury Brothers Cooling, Plumbing & Electrical:

Thank you, Jed! We appreciate you writing us such a kind review!

Review
Caleb- very polite, informative, and a valuable asset to Bradbury!
Jon - Willis, TX 77318
Response from Bradbury Brothers Cooling, Plumbing & Electrical:

Thank you, Jon! So happy to hear Caleb took great care of you!

Review
Jim was extremely professional! Great service!
Jill - Willis, TX 77318
Review
I was a first time customer and they definitely have my business. Scheduling was easy, they communicated well and performed all the things we needed done. I love that there was a text prior to the appt with Casey’s face. They think of safety and that’s great!
Kim - Willis, TX 77318
Review
J
Paul - Willis, TX 77318
Review
Very professional
Davy - Willis, TX 77318
Review
Great 👍
Aimee - Willis, TX 77318
Review
Very professional and courteous!! Educated on what needed to be done now and what can be done in the future to prevent wear and tear on plumbing system. Thank you!!
Aimee - Willis, TX 77318
Review
Same as always
Melissa - Willis, TX 77318
Response from Bradbury Brothers Cooling, Plumbing & Electrical:

Thank you for the 5 stars, Melissa!

Review
Malfunction
Sam - Willis, TX 77318
Review
He was Great! #10 or a 100%
Linda - Willis, TX 77318
Review
Mark did a great job and is very customer service first
Melissa - Willis, TX 77318
Response from Bradbury Brothers Cooling, Plumbing & Electrical:

Thank you, Melissa! We are so happy to hear that Marc took great care of you!

Review
Jeremy was efficient, polite and explained everything he was doing.
Kathleen - Willis, TX 77318
Response from Bradbury Brothers Cooling, Plumbing & Electrical:

Thank you for the 5 stars, Kathleen! We are so pleased to hear you had an excellent experience with our HVAC technician, Jeremy. We think he is pretty great, too!